5 changes: 5 additions & 0 deletions drivers/SmartThings/zigbee-thermostat/fingerprints.yml
Original file line number Diff line number Diff line change
@@ -1,4 +1,9 @@
zigbeeManufacturer:
- id: "SONOFF/TRV-ZBT"
deviceLabel: SONOFF TRV-ZBT
manufacturer: SONOFF
model: TRV-ZBT
deviceProfileName: thermostat-sonoff-trv-zbt
- id: "Vimar/02973-smart-wheel-thermostat"
deviceLabel: Vimar Smart Thermostat
manufacturer: Vimar
Expand Down
Original file line number Diff line number Diff line change
@@ -0,0 +1,38 @@
name: thermostat-sonoff-trv-zbt
Comment thread
KKlimczukS marked this conversation as resolved.
components:
- id: main
capabilities:
- id: temperatureMeasurement
version: 1
- id: thermostatHeatingSetpoint
version: 1
config:
values:
- key: "heatingSetpoint.value"
range: [5, 30]
- id: thermostatMode
version: 1
- id: battery
version: 1
- id: refresh
version: 1
categories:
- name: Thermostat
preferences:
- name: "childLock"
title: "Child lock"
description: "Enable or disable the child lock of the thermostat."
required: false
preferenceType: enumeration
definition:
options:
0: "Unlock"
1: "Lock"
default: 0
- name: "enterBluetoothPairing"
title: "Enter Bluetooth pairing"
description: "Enable to put the thermostat into Bluetooth pairing mode. The pairing window is controlled by the thermostat firmware."
required: false
preferenceType: boolean
definition:
default: false
12 changes: 12 additions & 0 deletions drivers/SmartThings/zigbee-thermostat/src/sonoff/can_handle.lua
Original file line number Diff line number Diff line change
@@ -0,0 +1,12 @@
-- Copyright 2026 SmartThings, Inc.
-- Licensed under the Apache License, Version 2.0

local function can_handle(opts, driver, device)
if device:get_manufacturer() == "SONOFF" and device:get_model() == "TRV-ZBT" then
return true, require("sonoff")
end

return false
end

return can_handle
321 changes: 321 additions & 0 deletions drivers/SmartThings/zigbee-thermostat/src/sonoff/init.lua
Original file line number Diff line number Diff line change
@@ -0,0 +1,321 @@
-- Copyright 2026 SmartThings, Inc.
-- Licensed under the Apache License, Version 2.0

local capabilities = require "st.capabilities"
local clusters = require "st.zigbee.zcl.clusters"
local cluster_base = require "st.zigbee.cluster_base"
local data_types = require "st.zigbee.data_types"
local generic_body = require "st.zigbee.generic_body"
local messages = require "st.zigbee.messages"
local zcl_messages = require "st.zigbee.zcl"
local zb_const = require "st.zigbee.constants"
local utils = require "st.utils"

local PowerConfiguration = clusters.PowerConfiguration
local Thermostat = clusters.Thermostat

local Battery = capabilities.battery
local Refresh = capabilities.refresh
local TemperatureMeasurement = capabilities.temperatureMeasurement
local ThermostatHeatingSetpoint = capabilities.thermostatHeatingSetpoint
local ThermostatMode = capabilities.thermostatMode

local SONOFF_CLUSTER = 0xFC11
local CHILD_LOCK_ATTR = 0x0000
local WORK_MODE_ATTR = 0x0018
local WORK_MODE_OFF = 0x01
local WORK_MODE_MANUAL = 0x03
local WORK_MODE_SCHEDULE = 0x04
local WORK_MODE_TEMP_MANUAL = 0x05

local DEFAULT_MIN_SETPOINT = 5
local DEFAULT_MAX_SETPOINT = 30
local SETPOINT_STEP = 0.5
local CHILD_LOCK_PREFERENCE = "childLock"
local BLUETOOTH_PAIRING_PREFERENCE = "enterBluetoothPairing"
local MIN_HEAT_SETPOINT_LIMIT_FIELD = "min_heat_setpoint_limit"
local MAX_HEAT_SETPOINT_LIMIT_FIELD = "max_heat_setpoint_limit"
local SUPPORTED_MODES = {
ThermostatMode.thermostatMode.off.NAME,
ThermostatMode.thermostatMode.heat.NAME,
ThermostatMode.thermostatMode.auto.NAME,
}

local CONFIGURATIONS = {
{
cluster = Thermostat.ID,
attribute = Thermostat.attributes.LocalTemperature.ID,
minimum_interval = 10,
maximum_interval = 300,
data_type = Thermostat.attributes.LocalTemperature.base_type,
reportable_change = 50,
},
{
cluster = Thermostat.ID,
attribute = Thermostat.attributes.OccupiedHeatingSetpoint.ID,
minimum_interval = 1,
maximum_interval = 600,
data_type = Thermostat.attributes.OccupiedHeatingSetpoint.base_type,
reportable_change = 50,
},
{
cluster = Thermostat.ID,
attribute = Thermostat.attributes.SystemMode.ID,
minimum_interval = 1,
maximum_interval = 600,
data_type = Thermostat.attributes.SystemMode.base_type,
},
{
cluster = Thermostat.ID,
attribute = Thermostat.attributes.MinHeatSetpointLimit.ID,
minimum_interval = 30,
maximum_interval = 21600,
data_type = Thermostat.attributes.MinHeatSetpointLimit.base_type,
reportable_change = 50,
},
{
cluster = Thermostat.ID,
attribute = Thermostat.attributes.MaxHeatSetpointLimit.ID,
minimum_interval = 30,
maximum_interval = 21600,
data_type = Thermostat.attributes.MaxHeatSetpointLimit.base_type,
reportable_change = 50,
},
}

local function get_setpoint_range(device)
local reported_min = device:get_field(MIN_HEAT_SETPOINT_LIMIT_FIELD)
local reported_max = device:get_field(MAX_HEAT_SETPOINT_LIMIT_FIELD)
local min = reported_min and (reported_min / 100) or DEFAULT_MIN_SETPOINT
local max = reported_max and (reported_max / 100) or DEFAULT_MAX_SETPOINT

if min > max then
min = DEFAULT_MIN_SETPOINT
max = DEFAULT_MAX_SETPOINT
end

return min, max
end

local function emit_setpoint_range(device)
local min, max = get_setpoint_range(device)
device:emit_event(ThermostatHeatingSetpoint.heatingSetpointRange({
value = {
minimum = min,
maximum = max,
step = SETPOINT_STEP,
},
unit = "C",
}, { visibility = { displayed = false } }))
Comment thread
KKlimczukS marked this conversation as resolved.
end

local function emit_supported_modes(device)
device:emit_event(ThermostatMode.supportedThermostatModes(SUPPORTED_MODES, {
visibility = { displayed = false },
}))
end

local function emit_mode(device, mode)
device:emit_event(ThermostatMode.thermostatMode[mode]())
end

local function command_argument(command, name)
if command.args ~= nil and command.args[name] ~= nil then
return command.args[name]
end

return command.named_args and command.named_args[name]
end

local function refresh(_, device)
local attributes = {
Thermostat.attributes.LocalTemperature,
Thermostat.attributes.OccupiedHeatingSetpoint,
Thermostat.attributes.SystemMode,
PowerConfiguration.attributes.BatteryPercentageRemaining,
}

for _, attribute in ipairs(attributes) do
device:send(attribute:read(device))
end
end

local function configure(driver, device)
device:configure()
refresh(driver, device)
device:send(Thermostat.attributes.MinHeatSetpointLimit:read(device))
device:send(Thermostat.attributes.MaxHeatSetpointLimit:read(device))
end
Comment thread
KKlimczukS marked this conversation as resolved.

local function added(_, device)
emit_supported_modes(device)
emit_setpoint_range(device)
end

local function init(driver, device)
for _, configuration in ipairs(CONFIGURATIONS) do
device:add_configured_attribute(configuration)
end
added(driver, device)
refresh(driver, device)
end

local function info_changed(_, device, _, args)
local old_preferences = args.old_st_store and args.old_st_store.preferences or {}
local child_lock = device.preferences[CHILD_LOCK_PREFERENCE]
if child_lock ~= nil and old_preferences[CHILD_LOCK_PREFERENCE] ~= child_lock then
device:send(cluster_base.write_attribute(
device,
data_types.ClusterId(SONOFF_CLUSTER),
data_types.AttributeId(CHILD_LOCK_ATTR),
data_types.validate_or_build_type(tonumber(child_lock) == 1, data_types.Boolean, "payload")
))
end

local bluetooth_pairing = device.preferences[BLUETOOTH_PAIRING_PREFERENCE]
if bluetooth_pairing == true and old_preferences[BLUETOOTH_PAIRING_PREFERENCE] ~= true then
local zcl_header = zcl_messages.ZclHeader({
cmd = data_types.ZCLCommandId(0x10),
})
zcl_header.frame_ctrl:set_cluster_specific()
device:send(messages.ZigbeeMessageTx({
address_header = messages.AddressHeader(
zb_const.HUB.ADDR,
zb_const.HUB.ENDPOINT,
device:get_short_address(),
device:get_endpoint(SONOFF_CLUSTER) or 1,
zb_const.HA_PROFILE_ID,
SONOFF_CLUSTER
),
body = zcl_messages.ZclMessageBody({
zcl_header = zcl_header,
zcl_body = generic_body.GenericBody(string.char(0x03, 0x01, 0x01)),
}),
}))
end
end

local function local_temperature_handler(_, device, value)
if value.value ~= 0x8000 and value.value ~= -32768 then
device:emit_event(TemperatureMeasurement.temperature({ value = value.value / 100, unit = "C" }))
end
end

local function heating_setpoint_handler(_, device, value)
if value.value ~= 0x8000 and value.value ~= -32768 then
device:emit_event(ThermostatHeatingSetpoint.heatingSetpoint({ value = value.value / 100, unit = "C" }))
end
end

local function setpoint_limit_handler(field)
return function(_, device, value)
if value.value ~= 0x8000 and value.value ~= -32768 then
device:set_field(field, value.value, { persist = true })
emit_setpoint_range(device)
end
end
end

local function system_mode_handler(_, device, value)
if value.value == Thermostat.attributes.SystemMode.OFF then
emit_mode(device, ThermostatMode.thermostatMode.off.NAME)
elseif value.value == Thermostat.attributes.SystemMode.AUTO then
emit_mode(device, ThermostatMode.thermostatMode.auto.NAME)
elseif value.value == Thermostat.attributes.SystemMode.HEAT then
emit_mode(device, ThermostatMode.thermostatMode.heat.NAME)
end
end

local function battery_handler(_, device, value)
device:emit_event(Battery.battery(utils.clamp_value(utils.round(value.value / 2), 0, 100)))
end

local function work_mode_handler(_, device, value)
if value.value == WORK_MODE_OFF then
emit_mode(device, ThermostatMode.thermostatMode.off.NAME)
elseif value.value == WORK_MODE_SCHEDULE then
emit_mode(device, ThermostatMode.thermostatMode.auto.NAME)
elseif value.value == WORK_MODE_MANUAL or value.value == WORK_MODE_TEMP_MANUAL then
emit_mode(device, ThermostatMode.thermostatMode.heat.NAME)
end
end

local function set_heating_setpoint(_, device, command)
local setpoint = command_argument(command, "setpoint")
if setpoint >= 40 then
setpoint = utils.f_to_c(setpoint)
end

local min, max = get_setpoint_range(device)
setpoint = utils.clamp_value(setpoint, min, max)
-- The TRV-ZBT persists heating setpoints in 0.5 C increments.
setpoint = math.floor((setpoint / SETPOINT_STEP) + 0.000001) * SETPOINT_STEP
device:send(Thermostat.attributes.OccupiedHeatingSetpoint:write(device, utils.round(setpoint * 100)))
device:emit_event(ThermostatHeatingSetpoint.heatingSetpoint({ value = setpoint, unit = "C" }))
end

local function set_mode(_, device, command)
local mode_to_system_mode = {
[ThermostatMode.thermostatMode.off.NAME] = Thermostat.attributes.SystemMode.OFF,
[ThermostatMode.thermostatMode.heat.NAME] = Thermostat.attributes.SystemMode.HEAT,
[ThermostatMode.thermostatMode.auto.NAME] = Thermostat.attributes.SystemMode.AUTO,
}
local mode = command_argument(command, "mode")
local system_mode = mode_to_system_mode[mode]
if system_mode == nil then
return
end

device:send(Thermostat.attributes.SystemMode:write(device, system_mode))
emit_mode(device, mode)
end

local function mode_setter(mode)
return function(driver, device, command)
set_mode(driver, device, { args = { mode = mode } })
end
end

local sonoff = {
NAME = "SONOFF TRV-ZBT",
capability_handlers = {
[Refresh.ID] = {
[Refresh.commands.refresh.NAME] = refresh,
},
[ThermostatHeatingSetpoint.ID] = {
[ThermostatHeatingSetpoint.commands.setHeatingSetpoint.NAME] = set_heating_setpoint,
},
[ThermostatMode.ID] = {
[ThermostatMode.commands.setThermostatMode.NAME] = set_mode,
[ThermostatMode.commands.off.NAME] = mode_setter(ThermostatMode.thermostatMode.off.NAME),
[ThermostatMode.commands.heat.NAME] = mode_setter(ThermostatMode.thermostatMode.heat.NAME),
[ThermostatMode.commands.auto.NAME] = mode_setter(ThermostatMode.thermostatMode.auto.NAME),
},
},
zigbee_handlers = {
attr = {
[PowerConfiguration.ID] = {
[PowerConfiguration.attributes.BatteryPercentageRemaining.ID] = battery_handler,
},
[Thermostat.ID] = {
[Thermostat.attributes.LocalTemperature.ID] = local_temperature_handler,
[Thermostat.attributes.OccupiedHeatingSetpoint.ID] = heating_setpoint_handler,
[Thermostat.attributes.MinHeatSetpointLimit.ID] = setpoint_limit_handler(MIN_HEAT_SETPOINT_LIMIT_FIELD),
[Thermostat.attributes.MaxHeatSetpointLimit.ID] = setpoint_limit_handler(MAX_HEAT_SETPOINT_LIMIT_FIELD),
[Thermostat.attributes.SystemMode.ID] = system_mode_handler,
},
[SONOFF_CLUSTER] = {
[WORK_MODE_ATTR] = work_mode_handler,
},
},
},
lifecycle_handlers = {
added = added,
init = init,
doConfigure = configure,
infoChanged = info_changed,
},
can_handle = require "sonoff.can_handle",
}

return sonoff
1 change: 1 addition & 0 deletions drivers/SmartThings/zigbee-thermostat/src/sub_drivers.lua
Original file line number Diff line number Diff line change
Expand Up @@ -3,6 +3,7 @@

local lazy_load_if_possible = require "lazy_load_subdriver"
local sub_drivers = {
lazy_load_if_possible("sonoff"),
lazy_load_if_possible("zenwithin"),
lazy_load_if_possible("fidure"),
lazy_load_if_possible("sinope"),
Expand Down
Loading
Loading