14 changes: 14 additions & 0 deletions NEWS.adoc
Original file line number Diff line number Diff line change
Expand Up @@ -505,6 +505,20 @@ https://github.com/networkupstools/nut/milestone/13
firmware model id is shared between product lines, correcting
`ups.power.nominal`, `ups.realpower.nominal` and the computed
`ups.load`. [issue #3500]
* Added read-only support for the Ragtech Easy Way units ("family 14",
"NEW/QUADRI" in the OEM device table; 21 models), which share the USB
ids of the Easy Pro but push, on their own, a 32-byte frame with a
checksum at 2560 baud instead of answering polls. The new `family` option
(`auto`, `10` or `14`) selects the protocol; by default the driver first
listens passively and only then falls back to the Easy Pro polling,
which is unchanged. No write command is known for these units, so
nothing is sent to them and no instant commands are offered. Only
the on-line and on-battery states, voltages, frequency, load, battery
and temperature were checked against captures of the OEM software.
The line speed is 2560 baud, set directly (no standard constant); frames
are accepted only if the constant registers match a reference confirmed
by two frames and the values are plausible, and the rarely seen status
bits need two consecutive frames. [issue #3755]

- `richcomm_usb` driver updates:
* Completed support for NUT standard USB configuration options, and fixed
Expand Down
21 changes: 21 additions & 0 deletions data/driver.list.in
Original file line number Diff line number Diff line change
Expand Up @@ -1322,6 +1322,27 @@
"Ragtech" "ups" "1" "Easy 2000 M2" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy 2200 TI" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy 2200 M2" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 500 TI" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 500 M1" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 500 M2" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 600 TI" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 600 M1" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 600 M2" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 700 TI" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 700 M1" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 700 M2" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 1200 TI" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 1200 M1" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 1200 M2" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 1300 TI" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 1300 M1" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 1300 M2" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 1400 TI" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 1400 M1" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 1400 M2" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 1600 TI" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 1600 M1" "" "ragtech (experimental)"
"Ragtech" "ups" "1" "Easy Way 1600 M2" "" "ragtech (experimental)"

"Raritan" "pdu" "3" "Intelligent PDU - Dominion PX" "no report, but should be supported" "snmp-ups (experimental)"
"Raritan" "pdu" "3" "Metered PDU - Raritan PM" "no report, but should be supported" "snmp-ups (experimental)"
Expand Down
100 changes: 97 additions & 3 deletions docs/man/ragtech.txt
Original file line number Diff line number Diff line change
Expand Up @@ -37,6 +37,14 @@ the Easy Pro "GT" series) speak the same protocol but may report a model
id that collides with a table entry, so the driver can pick the wrong VA
rating. Use the *va* option below to set the correct rating in that case.

A second protocol, "family 14", covers the Ragtech Easy Way units (21
models, Easy Way 500/600/700/1200/1300/1400/1600 in TI, M1 and M2
variants). They use the same USB ids but a different, push-only
protocol; see the *FAMILY 14 (EASY WAY)* section below. Support for
family 14 is *read-only* and was developed from captures of the OEM
software on one unit (an Easy Way TI 1400, sold as "Easy Way 1500 VA
GT"); the other 20 models come from the OEM device table only.

This driver is *experimental*. Polling, status decoding and the
`shutdown.stayoff` / `shutdown.stop` instant commands have been
verified on hardware; `shutdown.return` and `test.battery.start.deep`
Expand All @@ -50,6 +58,20 @@ EXTRA ARGUMENTS

This driver supports the following options in the *ups.conf*:

*family*='auto|10|14';;
Select the protocol family. The default, *auto*, first listens for a
few seconds without writing anything to the UPS: if it receives a
checksum-valid family 14 frame at 2560 baud, the unit is treated as
family 14;
otherwise the driver continues with the family 10 protocol, with the
serial settings it had before the listen. Set *family=10* on an Easy Pro
unit to skip the listen (and its start-up delay of about three seconds,
which also applies to `-k`) and to leave the port settings exactly as
earlier versions did. Set *family=14* to require the Easy Way protocol;
owners of an Easy Way unit are advised to do so, because if the automatic
listen ever misses the stream, the driver falls back to polling it with
family 10 commands, which that protocol does not use.

*iout_calib*='number';;
Per-unit output current calibration constant. If omitted (default),
the driver reads the value from register `0xF3` at startup. Set this
Expand Down Expand Up @@ -77,6 +99,75 @@ battery event. With this flag unset, `upsdrv_shutdown` logs the
refusal and exits with failure instead of cutting the output.


FAMILY 14 (EASY WAY)
--------------------

The Easy Way units transmit a 32-byte frame about every 1.3 seconds on
their own, at 2560 baud 8N1, without being asked. The driver only
reads: it never writes anything to a family 14 unit, it registers no
instant commands, and `upsdrv_shutdown` fails (so the `FSD` handling of
`upsmon` cannot power such a UPS off through this driver). If
*allow_shutdown* is set it is ignored with a warning. No write command
is known for this family: the OEM device table lists no actions for it
and none was seen in captures of the OEM software.

Unlike family 10, these units do use the line speed, so the port must be
at 2560 baud (not the usual 2400: that is the first speed listed for this
family in the OEM device table, and the OEM software uses it); the driver
sets that itself. Read at 2400 the stream is corrupted in a systematic
way: bit 7 of the bytes arrives set and bit 6 is unreliable, so most
frames fail the checksum, and a few corrupted ones still pass it. A
speed like 2560 has no standard constant, so the driver asks the system
for it directly (the `termios2` interface on Linux, the numeric speed on
BSD and macOS). If that fails, for instance on a platform without such
support, the driver logs a warning ("could not set 2560 baud; falling
back to 2400, expect corrupted frames") and uses 2400; the checks below
then drop most frames and the data will often be marked stale.

The 8-bit sum of the frame is a weak check (two bytes that both gain bit
7 add up to zero), so a frame is only accepted if it also passes these:

* Registers 0x00 to 0x09 (version, model and calibration constants) are
fixed in the unit. They must equal a reference, which is taken from two
consecutive checksum-valid frames having identical values there; nothing
is published before that, so the start-up takes a few seconds longer. If
frames keep being dropped for this reason for more than 30 seconds and
two consecutive ones agree on other values, those become the new
reference.
* The tap index is at most 3, the load at most 150 %, the temperature at
most 100 degrees C and the battery voltage between 6 and 18 V.
* `ups.alarm` entries, `OVER` and `LB` appear, and disappear, only after
two consecutive accepted frames agree. `OL`, `OB` and `CHRG` follow
each accepted frame, so a mains cut is reported without that delay.

Published data: `ups.mfr`, `ups.model`, `ups.firmware`,
`ups.power.nominal`, `ups.temperature`, `ups.load`, `ups.status`,
`ups.alarm`, `input.voltage`, `input.voltage.nominal`,
`output.voltage`, `output.voltage.nominal`, `output.frequency`,
`output.frequency.nominal`, `battery.voltage`, `battery.voltage.nominal`
and `battery.charge`. There is no output current. `ups.load` is the
load ratio reported by the firmware. `ups.power.nominal` is the number
in the model name, with the same convention as for family 10;
`ups.realpower.nominal` is not published because the OEM table does not
say whether that number is VA or watts. `battery.charge` is an estimate
computed from the battery voltage, as in the OEM software.

What was observed on hardware (mains cut and restored on one TI unit):
`OL` and `OB` follow the firmware's on-battery flag, and the voltages,
frequency, load, battery voltage and temperature match the values shown
by the OEM software. What is inferred from bit names in the OEM table
and was *not* observed: `CHRG` (shown while on mains and the
battery-full flag is clear), `LB`, `OVER`, and every `ups.alarm` entry.
`BOOST`, `TRIM` and the beeper are not reported. The M1 and M2
variants follow the OEM table, but the output voltage formula of the M2
(220 V) models in that table is the 115 V one with different tap factors,
which looks doubtful, so treat `output.voltage` on those with suspicion
until someone confirms it.

If no accepted frame arrives for more than five seconds the data is marked
stale.


CAVEATS
-------

Expand All @@ -86,9 +177,12 @@ are interpreted by the UPS as a remote shutdown signal -- never run
this driver alongside other software that toggles those lines on the
same device node.

Replies are framed by a 0xAA start byte and have no checksum; the
driver re-synchronizes by scanning for the start byte after any
short read.
On family 10, replies are framed by a 0xAA start byte and have no
checksum; the driver re-synchronizes by scanning for the start byte
after any short read. On family 14 the frames start with `55 55 AE` and
end with an 8-bit sum; the driver checks every frame whose sum is right
against the constants and ranges described above, and keeps the newest
one that passes.


AUTHOR
Expand Down
3 changes: 2 additions & 1 deletion docs/nut.dict
Original file line number Diff line number Diff line change
@@ -1,4 +1,4 @@
personal_ws-1.1 en 3917 utf-8
personal_ws-1.1 en 3918 utf-8
AAC
AAS
ABI
Expand Down Expand Up @@ -1146,6 +1146,7 @@ QQ
QQQ
QRI
QTS
QUADRI
QVFW
QWS
QinHeng
Expand Down
4 changes: 2 additions & 2 deletions drivers/Makefile.am
Original file line number Diff line number Diff line change
Expand Up @@ -252,7 +252,7 @@ bestfcom_SOURCES = bestfcom.c
bestfortress_SOURCES = bestfortress.c
bestuferrups_SOURCES = bestuferrups.c
bestups_SOURCES = bestups.c
ragtech_SOURCES = ragtech.c
ragtech_SOURCES = ragtech.c ragtech_speed.c
ragtech_LDADD = $(LDADD_DRIVERS_SERIAL)
blazer_ser_SOURCES = blazer.c blazer_ser.c
blazer_ser_LDADD = $(LDADD_DRIVERS_SERIAL) -lm
Expand Down Expand Up @@ -557,7 +557,7 @@ dist_noinst_HEADERS = \
hidparser.h hidtypes.h ietf-mib.h libhid.h libshut.h nut_libusb.h libwinhid.h liebert-hid.h \
main.h mge-hid.h mge-mib.h mge-utalk.h \
mge-xml.h microdowell.h microsol-apc.h microsol-common.h netvision-mib.h netxml-ups.h nut-ipmi.h oneac.h \
powercom.h powerpanel.h powerp-bin.h powerp-txt.h powervar_cx.h raritan-pdu-mib.h \
powercom.h powerpanel.h powerp-bin.h powerp-txt.h powervar_cx.h ragtech_speed.h raritan-pdu-mib.h \
safenet.h serial.h sms_ser.h snmp-ups.h solis.h tripplite.h tripplite-hid.h \
upshandler.h usb-common.h usbhid-ups.h powercom-hid.h compaq-mib.h idowell-hid.h microdowell-hid.h \
apc_common.h apcmicrolink-maps.h apcmicrolink.h apcmicrolink-usb.h apcsmart.h apcsmart_tabs.h apcsmart-old.h apcupsd-ups.h cyberpower-mib.h riello.h openups-hid.h \
Expand Down
Loading
Loading